Teach you how to maintain and repair the bottle blowing machine

Update: 2022/04/28
Abstract:

1. No feeding at the feeding position: several situatio […]

1. No feeding at the feeding position: several situations need to be checked: whether the hopper of the blow molding machine has run out of material, if so: need to feed quickly No: please check whether the control contactor of the hoist is in the power-on state, if yes When the power is on, check whether the motor is powered and loaded, because this situation is likely to be caused by the preform (preform) stuck on the lifting belt, and the simple method is to manually lift it. If the control contactor of the inspection hoist is not energized, please check whether the preform detection electric eye and the reflector are not in the same line.

2. Feeding the old card feeding tray: This situation is a headache. From experience, if the length of the preform (preform) of the blow molding machine is longer and the cutting weight is larger, then this phenomenon is relatively rare. of.

3. The bottle cannot be taken out of the mold after blowing. First, the mold should be opened, and the mold should be opened and closed manually. If it is normal, run it in the dry running state, if it is normal. Please check your exhaust time setting. If the exhaust setting is normal and the failure occurs every time you blow the bottle, then it can be judged that it is the problem of the exhaust valve. Please open the exhaust valve to check the condition of its spring and seal (this There is also a phenomenon that the exhaust sound is relatively loud or there is an unclean sound). If you encounter a situation where the mold cannot be opened by chance due to the normal production of many molds, please check whether the clamping pin has a segmented screw in it. In addition, please check whether the clamping force is too large. Standard readjustment.
4. Whether the position of the bottle is always pinched by the manipulator is misplaced.

0
Views: 3,197
Contact Us